FEATURES
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
  • Microprocessor Based with Printer Interface
  • Four Measurements in Single Aspiration
  • Curve Calibration Programmability Using Max. of 5 Standards
  • Data Processing Through Curve Fitting Techniques, Least Square, Quadratic
  • Multiple Calibration Curve Saving Facility
  • Sample Data Storage Facility
  • Printer Attachment Facility
  • Direct Results In ppm and meq
  • Useful for both Medical & Soil Testing Applications

Microprocessor Flame Photometer, Model-1382 is an ideal instrument for the determination of sodium, Potassium, Calcium and Lithium. It uses the latest Microcontroller technology and advanced engineering techniques so as to give enhanced and reproducibility. It has soft touch membrane key for ease of operations. the solution is aspirated through an automiser, Air sample and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. The color of the flame is changed depending upon the concentration of elements present. Radiations from the flame passes through the sensing system and specific narrow band interference filter which permits only the characteristic radiation to pass to the photo-detector. The output of the photo-detector is then processed by the microcontroller and the final results are displayed on the digital display. The System has 5-Point calibration facility and no linearity correction is provided through an automatic curve fitting software. Facility has been provided for re-standardization with a single standard, thereby, eliminating the need of the multiple standards once a calibration has been performed.

SPECIFICATIONS

Mode General Serum Urine
Range
Na: 0.1-100 ppm
Upto 250 meq/l, 1:100 dil

K: 0.1-100 ppm
Upto 250 meq/l, 1:100 dil

Ca: 15-100 ppm
Upto 250 meq/l, 1:100 dil

Li: 0.5-100 ppm
Upto 250 meq/l, 1:100 dil

Na: 0-200
1:100 dil

K: 0-10
1:100 dil

Ca: - Li: 0-2
1:5 dil

Na: 0-250
1:100 dil

K: 0-100
1:100 dil

Ca: - Li: 0-10
1:2 dil
Sensitivity General Mode: Na:0.5 ppm, K:0.5 ppm, Li:0.5 ppm, Ca:15 ppm
Filters Na & K Supplied (Ca & Li are optional at extra cost)
Resolution 0.1 ppm/meq
Reproducibility + 2% FS, &± 2 Digits
Curve Fit Accuracy + 2% FS
Display 20 x 4 Alphanumeric backlit LCD display
Average Time In-built in Software
Flame System LPG & dry oil free air
Detector Silicon Photodiode
Calibration Upto 5-Point Calibration with curve fitting software
Gas Control Adjustable with knobs
Ignition System Auto Ignition
Automiser Axial flow type
Printer Provision for attachment of Dot-Matrix Printer of HP Laserjet/Inkjet Printer (non-win printers) with centronics parallel interface
RS-232C Interface Available (PC Software at extra cost)
Power 230 V + 10% AC, 50 Hz
Dimensions 365 x 245 x 220 mm (L x B x H) (Approx.)
Weight Main Unit : 7.5 Kg. (Approx.)
COMPRESSOR UNIT
Air Supply By oil free mini compressor unit with pressure regulator
Combustion Gas LPG Controlled by precision regulator
Power 230 V + 10% AC, 50 Hz
Dimensions 290 x 255 x 210 mm (L x B x H) (Approx.)
Weight 8 Kg (Approx.)
Note : Specifications are subject to change due to continuous improvements.